Customization: | Available |
---|---|
Breaking Capacity: | Low Voltage Circuit Breakers |
Operation: | Manual Type |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type | JZM1-63L JZM1-63M | JZM1-125L JZM1-125M | JZM1-250L JZM1-250M | ||||||||||||
Rated frame level current lnm(A) | 63 | 125 | 250 | ||||||||||||
Rated current ln (A) | 10, 12, 16, 20, 25, 32, 40, 50, 63 | 16, 20, 25, 32, 40, 50, 63, 80, 100, 125 |
125, 160, 180, 200, 225, 250 | ||||||||||||
Rated insulated voltage Ui(AC V) | 500 | 800 | 800 | ||||||||||||
Rated impulse-stand voltage Ui(V) | 8000 | 8000 | 8000 | ||||||||||||
Rated working voltage Ue(AC V) | 400/415 | 400/415 | 400/415 | ||||||||||||
Poles | 3 | 4 | 3 | 4 | 3 | 4 | |||||||||
Rated limited short-circuit breaking capacity level | L | M | L | M | L | M | L | M | L | M | L | M | |||
Rated limited short-circuit breaking capacity lcu(KA) | 400/415V | 20 | 30 | 20 | 30 | 30 | 50 | 30 | 50 | 35 | 50 | 35 | 50 | ||
Rated working short-circuit breaking capacity lcs(KA) | 400/415V | 15 | 22.5 | 15 | 22.5 | 22.5 | 37.5 | 22.5 | 37.5 | 26.25 | 37.5 | 26.25 | 37.5 | ||
Operation characteristic (Times) | Connected | 2000 | 2000 | 1500 | |||||||||||
Break | 10000 | 10000 | 8500 | ||||||||||||
Outlook dimension | L | 135 | 150 | 165 | |||||||||||
W | 78 | 103 | 92 | 122 | 107 | 142 | |||||||||
H | 73.5 | 81.5 | 72 | 88 | 86 | 103 | |||||||||
Weight(g) | 735 | 849 | 1464 | 1952 | 1257 | 1493 | 1493 | 1900 | 1714 | 2014 | 1900 2014 | ||||
Arcing distance(mm) | ≤50 | ≤50 | ≤50 |
Type | JZM1-400M JZM1-400H | JZM1-630M JZM1-630H | JZM1-800H | |||||||||
Rated frame level current lnm(A) | 400 | 630 | 800 | |||||||||
Rated current ln (A) | 225, 250, 315, 350, 400 | 400, 500, 630 | 630, 700, 800 | |||||||||
Rated insulated voltage Ui(AC V) | 800 | 800 | 800 | |||||||||
Rated impulse-stand voltage Ui(V) | 8000 | 8000 | 8000 | |||||||||
Rated working voltage Ue(AC V) | 400/415 | 400/415 | 400/415 | |||||||||
Poles | 3 | 4 | 3 | 4 | 3 | 4 | ||||||
Rated limited short-circuit breaking capacity level | M | H | M | H | M | H | M | H | H | H | ||
Rated limited short-circuit breaking capacity lcu(KA) | 400/415V | 50 | 70 | 50 | 70 | 50 | 70 | 50 | 70 | 80 | 80 | |
Rated working short-circuit breaking capacity lcs(KA) | 400/415V | 37.5 | 52.5 | 37.5 | 52.5 | 37.5 | 52.5 | 37.5 | 52.5 | 60 | 60 | |
Operation characteristic (Times) |
Connected | 1000 | 1000 | 500 | ||||||||
Break | 5000 | 4000 | 3000 | |||||||||
Outlook dimension |
L | 257 | 270 | 280 | ||||||||
W | 150 | 198 | 182 | 240 | 210 | 280 | ||||||
H | 106.5 | 110 | 115.5 | |||||||||
Weight(g) | 5420 | 7443 | 6116 | 7116 | 7116 | 9929 | 8526 | 11731 | ||||
Arcing distance(mm) | ≤50 | ≤100 | ≤100 |